Back to Top

1
Hi, Guest!
  • Culter Hammer

Culter Hammer

Update Terakhir
:
12 / 12 / 2019
Min. Pembelian
:
1 Unit

Harga

CALL

Detail Culter Hammer

Circuit Breaker, Dry type Transformer, Safety Switch & Enclosed CB, Panelboard, Switchboard, Switchgear, Transfer Switch, and Metering Device & Protection Relays By Culter Hammer. A. Circuit Breaker MCB Industrial – Quicklag MCB 1/ 2/ 3 Pole, 15 – 100 A, 10kA/ 22kA/ 42kA/ 65kA Mounting: Plug-On, Bolt-On, Cable In / Cable Out 1. Industrial – Quicklag Ground Fault Sensitivity: 5 mA / 30 mA Mounting: Plug-On, Bolt-On 2. Industrial – IEC MCB 1/ 2/ 3/ 4 Pole, 1 – 63 A, 6kA/ 10kA 3. Industrial – IEC Ground Fault Sensitivity: 10 mA / 30 mA / 300 mA B. Circuit Breaker MCCB 1. Series C – MCCB Designed to provide circuit protection for low voltage distribution systems Available 15 – 2500 A, 14kA – 100kA Long, Short, Instantaneous, & Ground Fault trip function 2. Motor Circuit Protector – HMCP Available 3 – 1200A for motor starter size 0 – 8 3. Mining Service Breaker Proven & verified during hundreds of hours of field testing in harsh mine environment Available in 600VAC & 1000Y/ 577 VAC, 15 – 2000A C. Circuit Breaker – Power Circuit Breaker 1. DS & DS II Power Breaker Rugged metal frame construction, draw out & fixed Up to 635 VAC, 200 – 4000 Amp, 30 – 200 kA 100% rating at full continuous current 2. Digitrip trip unit family with microprocessor based true rms sensing 3. Magnum DS, NEMA ACB Up to 635VAC, 200 – 6000A, 42 – 200 kA 4. Magnum IEC ACB Up to 690VAC, 200 – 6300A, 42 – 100 kA 5. Series NRX ACB Small size, IEC rating 800 – 1600A, 65kA D. Safety Switch 1. Heavy Duty Safety Switch Used in heavy commercial & industrial applications Rated 30 – 1200A, Fusible and Non Fusible Available in NEMA 1, 12, 3R, 4 and 4X Enclosure 2. NEMA 7/ 9 – Hazardous Location Disconnect Switch Made from cast aluminium, suited for harsh industrial applications, like petrochemical and mining operations Rated 600VAC, 30 – 200A, Fusible and Non Fusible 3. Double Throw Switch Used to transfer service from a normal power source to an alternate source Rated 600VAC, 250VDC, 30 – 800 A, Fusible and Non Fusible E. Transfer Switch 1. Manual / Non-Automatic Transfer Switch Totally enclosed for maximum arc suppression and isolation during power transfer Permits safe & convenient manual transfer of power under load via external pushbutton initiated operation Rated 600 VAC, 30 – 4000 A in 2, 3, and 4 poles Available in open, NEMA 1, 3R, 12, 4 and 4X Enclosure 2. Wall Mounted Automatic Transfer Switch Rated 600 VAC, 30 – 1000 A in 2, 3, and 4 poles Available in open, NEMA 1, 3R, and 12 Enclosure Open transition using ATC 300 or ATC 600 IQ transfer Logic Controller 3. Free Standing Automatic Transfer Switch Rated 600 VAC, 600 – 5000 A in 2, 3, and 4 poles Available in NEMA 1 and NEMA 3R enclosure Using Magnum ACB and available in drawout type Open transition using ATC-600 IQ Transfer Logic Contoller Closed transition using ATC-800 IQ Transfer Logic Controller Fastest switching times available ( < 3 cycles) 4. Bypass Isolation Transfer Switch Designed for applications where maintenance, inspection & testing must be performed while maintaining continuous power to load Rated 600 VAC, 200 – 5000 A in 2, 3, and 4 poles Available in NEMA 1 and NEMA 3R enclosure Available in Automatic or Non Automatic Transfer In Automatic using ATC-600 for open transition and ATC-800 for closed transition 5. Closed Transition Soft Load Transfer Switch Utilized an integrated microprocessor based power controller ( ATC-5000) to make active paralleling of two power sources possible It manages the speed governor & voltage regulator or the generator set to bring the two sources into synchronization It can also be used as a peak shaving switch by paralleling the generator set with the utility source during times of high electrical demand Rated 600 VAC, 800 – 3200 A, available in NEMA 1 and 3R enclosure Using Magnum ACB and available in drawout type F. Panel Board 1. Type PRL1a & PRL2a Using Quicklag MCB, Plug-On or Bolt-On Rated 480Y/ 277 VAC, 240 VAC, 125/ 250 VDC Main 400 A maximum, branch 100 A maximum Fast Installation 2. Type PRL1a & PRL2a Using MCCB or fusible Switches, Plug-On or Bolt-On Rated 600 V, 480 V, 240 VAC, 250 VDC Main 1200 A maximum, branch 1200 A maximum G. Switch Board Rated 600 V, 480 V, 240 VAC, 250 VDC 6000 A maximum main bus rating Main Devices: MCCB, 400 – 2500 A, fixed or drawout Magnum DS ACB, 800 – 5000 A, fixed or drawout Feeder devices: MCC, 800 – 2500 A, fixed Magnum DS ACB, 800 – 4000 A Available in NEMA 1 & 3R enclosure Front Accessible H. Switchgear 1. Magnum DS Switchgear Rated 600 VAC maximum Using Magnum DS ACB until 6000 A Vertical and cross bus rating are 2000, 3200, 4000, 5000, and 6000 Ampere 8000 & 10000 A continuous cross bus ratings are also available Silver-plated copper main buses are standard. The plating is over the entire length of the bar, not just at the joints Standard bracing is 100 kA Available in NEMA 1 & 3R enclosure 2. Arc Resistant Switchgear - Low voltage arc-resistant switchgear protects operating and maintenance personnel from dangerous arcing faults by redirecting or channeling the arc energy out the top of the switchgear, regardless of the origination location of the arc - Patented bellows design allowing drawout of breaker into the disconnected position with the door closed, while simultaneously protecting the operator from any dangerous gasses during an arc event I. Contactor 1. NEMA Contactor Size 00 – 8, max 900 HP Motor IEC Contactor 7 – 1215 A, max 900 HP Motor HVAC Contactor Designed for service in applications such as refrigeration, air conditioning and resistance heating DPCK Contactor Designed for applications include mining equipment, welding equipment, heating & air conditioning applications & other loads that require a compact heavy-duty contactor rated up 1500 VAC 2. DC Contactor Capable switching up to 2000 VDC loads, rated at 1400 A continuous Lighting Contactor Designed to handle the switching of tungsten or ballast ( fluorescent, mercury / sodium vapor, and quartz) load Available in electrically held, mechanically held, and magnetically latched Number of poles until 12 poles for 30 A rated For magnetically latche rated until 400 A J. Soft Starter 1. Type TL, S701 Solid State Controller - Low cost option for soft starting small 3-phase motor until 15HP - Provide the overload protection for the motor 2. Type S752, S801, S811 Solid State Starter Rated up to 690VAC, 11 – 1000 Ampere Operations: voltage ramp start, current limit start, kick start, soft stop, and optional pump control Equipped with DIM ( Digital Interface Module) for metering, monitoring & diagnostic capabilities Protective features: overload, jam, stall, over temperature, phase loss / imbalance / reversal, shorted / open SCR detection, low current, low / high voltage K. Adjustable Frequency Drive 1. MVX 9000 Micro Drive Provide variable speed control for three phase motor applications up to 10 HP Sensorless Vector Control with auto tuning Built-in dynamic braking chopper & serial communication ( RS-485) port 2. SVX 9000 General Purpose Drive Robust design, proven 500, 000 hours MTBF Rated: 380 – 500V, 1 – 1900 HP 525 – 690V, 2 – 2000 HP Available in open chassis, NEMA 1 & 12 enclosure 3. CPX 9000 Clean Power 18 Pulse Drive Use advanced 18-pulse, clean power, technology that significantly reduces line harmonics at the drive input terminals, resulting in one of the purest sinusoidal wave forms available Applications in the industries where harmonics are a concern Rated: 480VAC, 25 – 700 HP in NEMA 1 enclosure 4. LCX 9000 Liquid Cooled Drive The LCX9000 drives are liquid-cooled products that utilize potable water or a water-glycol mixture as a cooling medium Space savings up to 70% compared to just the power module of a similarly rated air-cooled drive Rated: 380 – 500V, 10 – 1800 HP; 525 – 690V, 200 – 2000 HP L. Enclosed Control Enclosure type 1, 12, 3R, 4, 4X, and 7/ 9 Hazardous Location Component inside the enclosure: Motor Disconnecting Switch: circuit breaker and disconnect switch Motor controller: contactor, starter, soft starter, and inverter Power Supply: phase to neutral and control power transformer ( CPT) Cover Control: selector switch, push button, and pilot light M. Motor Control Center ( MCC) 1. Freedom 2100 MCC Fabricated in Fayetteville, USA Modular, framed design permits structure arrangement to be tailored to exactly meet any control & distribution requirement NEMA 1, 2, 12, and 3R enclosure Copper horizontal bus 600 – 3200 A Fully rated copper vertical bus 300 – 1200 A 42kA, 65kA, and 100kA bus bracing Labyrinth barriers for insulated & isolated vertical bus All components are wired in accordance with NEC and UL standards 2. FlashGard MCC FlashGard addresses the dangers associated with an arc flash event and help prevent injury from electric shock, arc-flash burn, and arc-blast impacts FlashGard offers an insulated horizontal bus, an insulated labyrinth vertical bus, shutters to isolate the vertical bus when a unit is removed, and finger-safe components inside the units To reduce the time-available fault current FlashGard is offering an Arc Reduction Maintenance System ( ARMS) , applied to the breaker feeding the MCC to reduce trip time during an arc flash Maintaining a closed-door unit Removing voltages dangerous to life N. Metering Devices 1. IQ 100 Low cost meter, no communication Monitored values: current, voltage, & frequency 2. IQ 200 & IQ 300 Phase current, voltage ( L-L, L-N) , frequency, power factor System & per-phase power ( watthours, varhours, VA hours) System demand ( watt, VA, var demand) True rms metering of distorted current & voltage up to the 31st harmonic ( % THD) Recorded min & max of most values Digital & analog I/ O Built in INCOM or Modbus communication 3. IQ DP-4000 & IQ Analyzer Monitored values: rms sensing, current, voltage, frequency, power factor, power, energy, % THD current & voltage, min & max values Digital & analog I/ O Built in INCOM / Ethernet / Modbus communication IQ DP-4000 had protective & event alarming features: under/ over voltage, phase loss / reversal / unbalance, and optional current & voltage demand threshold IQ Analyzer had LCD display 4. Power Xpert 2 pieces design: Power Xpert Meter Module & Power Xpert Graphic Display ( support up to 16 PX Meter Module) Optional Power Xpert Embedded Web Server Both graphic display & web server present real time, historical, & event information in a browser-style graphical format to interpret key circuit such as: Current loading, voltage & power level, power factor, energy usage, power quality measurement, harmonic plot, and disturbance & transient waveform Support E-mail Notification with the optional LAN/ WAN Ethernet Comm Expansion Card O. Protective Relay 1. Manual / Non-Automatic Transfer Switch Totally enclosed for maximum arc suppression and isolation during power transfer Permits safe & convenient manual transfer of power under load via external pushbutton initiated operation Rated 600 VAC, 30 – 4000 A in 2, 3, and 4 poles Available in open, NEMA 1, 3R, 12, 4 and 4X Enclosure 2. MP – 3000 / 4000 Motor Protection Relay Provide motor overload, stall, short circuit, phase unbalance, over/ under voltage, underpower, power factor, & ground fault protection MD – 3000 Motor / Generator Differential Relay P. MV Circuit Breaker 1. VCP-W Medium Voltage Circuit Breaker Common platform: 5– 38 kV, 16– 75 kA, 600– 6000A Numerous product variations: narrow design, extra capability and generator breaker designs Built and tested to meet ANSI, IEC and GB standards 2. VCP-T Medium Voltage Circuit Breaker Common platform: 5– 15 kV, 16– 40 kA, 600– 2500A Compact: 60% smaller & 50% lighter than comparable breakers Designed for use where space is at a premium Spring & magnetic actuated mechanisms are available Built and tested to meet ANSI and IEC standards Q. MV Contactor SL Medium Voltage Power Contactor Using leading edge vacuum technology Voltage range 2200 to 7200 V Ampere rating: 160 / 200 / 360 / 400 / 800 A with induction motor horsepower until 10000 HP Field adjustable coil voltages & drop-out times Long life – 100, 000 electrical operations and over 1 million mechanical operations Universal altitude versions ranging from -3500M to + 5000M R. MV Soft Starter MV 811 Medium Voltage Soft Starter Intelligent choice for MV mechanical components to avoid coupling & shaft damage, prevent rotor & winding failure, and stop drive belt squeal and reakage Ratings: 100 to 1500 hp at 2400 volts 200 to 2500 hp at 4160 volts NEMA 1, 1A, 12 and 3R enclosures Operations: ramp start, current limit start, kick start, soft stop, and optional pump control Internal run bypass contactor which significantly reduces the internal heating created by the SCRs S. MV adjustable Frequency Drive AMPGARD SC 9000 MV Drive Designed for use with induction or synchronous motor at 2400 to 4160 volts up to 5750 horsepower The SC 9000’ s integrated phase shifting isolating transformer/ 24 pulse converter, coupled to a 3-level inverter topology, assures minimum component usage and reduces harmonics output. Specialized design and high-density packaging yields the smallest medium voltage drive in the industry The SC 9000 modular roll-in/ roll-out inverter design significantly reduces MTTR Can be supplied as a stand-alone drive or directly connected to other AMPGARD products T. MV Motor Starter AMPGARD Motor Starter Designed as integrated, complete units precisely matched to motor ratings, at 2200 – 7200 volts, up to 8000 Hp With an innovative design that enables easier installation, maintenance, and long life, Starters for motors: full voltage, reduced voltage ( either reactor or autotransformer type) , soft starter and drive Full coordination between fuse and contactor provides seamless protection U. MV Switchgear 1. MVS Fusible Switch Provides safe, reliable switching and fault protection for MV circuits rated from 2.4 kV through 38 kV Ideal for applications in a lower duty cycle operation environment, while providing a cost-effective option Continuous and load-break ratings: 600 A and 1200 A available at 5kV and 15kV Availabe in fusible and non fusible Visibility of actual blade position improves safety by providing positive assurance of circuit de-energization Can be equipped with motor operator to provides the safety, convenience, and coordination inherent in remote switch operation 2. MEF Front Accesible Switchgear Flexible, cost effective & space-efficient MV switchgear Available in ratings of 5 & 15 kV with 600, 1200, & 2000 A Truly front accessible construction eases installation, maintenance, and saves space in an electrical room Using Eaton’ s VCP-TL breaker’ s integral self-powering trip unit eliminates the need for an external power source in addition to a linear actuator that boasts 100, 000 mechanical operations Flexible configurations and standard building blocks provide easy scalability 3. MEB / MSB Switchgear Eaton' s MEB / MSB switchgear is an integrated assembly of a visible load-break disconnect switch, bus, fixed / drawout mounted vacuum circuit breaker, and control devices, which are integrated electrically & mechanically for circuit protection Ratings: 4.76 to 15 kV, 1200 A max Using Eaton’ s VCP-T breaker’ s up to 1200 A Also available with Arcflash Reduction Maintenance System 4. VCP-W Metal Clad Switchgear VCP-W metal-clad switchgear with type VCP-W vacuum breakers, provides centralized control and protection in industrial, commercial, and utility installations involving generators, motors, feeder circuits, and transmission and distribution lines. Ratings from 4.76 kV through 38 kV, Maintenance requirements are minimized by the use of enclosed long-life vacuum interrupters, and the component arrangements and drawers allow easy access
Tampilkan Lebih Banyak
Kontak Kami