Detail Culter Hammer
Circuit Breaker, Dry type Transformer, Safety Switch & Enclosed CB, Panelboard, Switchboard, Switchgear, Transfer Switch,
and Metering Device & Protection Relays By Culter Hammer.
A. Circuit Breaker MCB
Industrial – Quicklag MCB
1/ 2/ 3 Pole, 15 – 100 A, 10kA/ 22kA/ 42kA/ 65kA
Mounting: Plug-On, Bolt-On, Cable In / Cable Out
1. Industrial – Quicklag Ground Fault
Sensitivity: 5 mA / 30 mA
Mounting: Plug-On, Bolt-On
2. Industrial – IEC MCB
1/ 2/ 3/ 4 Pole, 1 – 63 A, 6kA/ 10kA
3. Industrial – IEC Ground Fault
Sensitivity: 10 mA / 30 mA / 300 mA
B. Circuit Breaker MCCB
1. Series C – MCCB
Designed to provide circuit protection for low voltage distribution systems
Available 15 – 2500 A, 14kA – 100kA
Long, Short, Instantaneous, & Ground Fault trip function
2. Motor Circuit Protector – HMCP
Available 3 – 1200A for motor starter size 0 – 8
3. Mining Service Breaker
Proven & verified during hundreds of hours of field testing in harsh mine environment
Available in 600VAC & 1000Y/ 577 VAC, 15 – 2000A
C. Circuit Breaker – Power Circuit Breaker
1. DS & DS II Power Breaker
Rugged metal frame construction, draw out & fixed
Up to 635 VAC, 200 – 4000 Amp, 30 – 200 kA
100% rating at full continuous current
2. Digitrip trip unit family with microprocessor based true rms sensing
3. Magnum DS, NEMA ACB
Up to 635VAC, 200 – 6000A, 42 – 200 kA
4. Magnum IEC ACB
Up to 690VAC, 200 – 6300A, 42 – 100 kA
5. Series NRX ACB
Small size, IEC rating 800 – 1600A, 65kA
D. Safety Switch
1. Heavy Duty Safety Switch
Used in heavy commercial & industrial applications
Rated 30 – 1200A, Fusible and Non Fusible
Available in NEMA 1, 12, 3R, 4 and 4X Enclosure
2. NEMA 7/ 9 – Hazardous Location Disconnect Switch
Made from cast aluminium, suited for harsh industrial applications, like petrochemical and mining operations
Rated 600VAC, 30 – 200A, Fusible and Non Fusible
3. Double Throw Switch
Used to transfer service from a normal power source to an alternate source
Rated 600VAC, 250VDC, 30 – 800 A, Fusible and Non Fusible
E. Transfer Switch
1. Manual / Non-Automatic Transfer Switch
Totally enclosed for maximum arc suppression and isolation during power transfer
Permits safe & convenient manual transfer of power under load via external pushbutton initiated operation
Rated 600 VAC, 30 – 4000 A in 2, 3, and 4 poles
Available in open, NEMA 1, 3R, 12, 4 and 4X Enclosure
2. Wall Mounted Automatic Transfer Switch
Rated 600 VAC, 30 – 1000 A in 2, 3, and 4 poles
Available in open, NEMA 1, 3R, and 12 Enclosure
Open transition using ATC 300 or ATC 600 IQ transfer
Logic Controller
3. Free Standing Automatic Transfer Switch
Rated 600 VAC, 600 – 5000 A in 2, 3, and 4 poles
Available in NEMA 1 and NEMA 3R enclosure
Using Magnum ACB and available in drawout type
Open transition using ATC-600 IQ Transfer Logic Contoller
Closed transition using ATC-800 IQ
Transfer Logic Controller
Fastest switching times available
( < 3 cycles)
4. Bypass Isolation Transfer Switch
Designed for applications where maintenance, inspection & testing must be performed while maintaining continuous power to load
Rated 600 VAC, 200 – 5000 A in 2, 3, and 4 poles
Available in NEMA 1 and NEMA 3R enclosure
Available in Automatic or Non Automatic Transfer
In Automatic using ATC-600 for open transition and ATC-800 for closed transition
5. Closed Transition Soft Load Transfer Switch
Utilized an integrated microprocessor based power controller ( ATC-5000) to make active paralleling of two power sources possible
It manages the speed governor & voltage regulator or the generator set to bring the two sources into synchronization
It can also be used as a peak shaving switch by paralleling the generator set with the utility source during times of high electrical demand
Rated 600 VAC, 800 – 3200 A, available in NEMA 1 and 3R enclosure
Using Magnum ACB and available in drawout type
F. Panel Board
1. Type PRL1a & PRL2a
Using Quicklag MCB, Plug-On or Bolt-On
Rated 480Y/ 277 VAC, 240 VAC, 125/ 250 VDC
Main 400 A maximum, branch 100 A maximum
Fast Installation
2. Type PRL1a & PRL2a
Using MCCB or fusible Switches, Plug-On or Bolt-On
Rated 600 V, 480 V, 240 VAC, 250 VDC
Main 1200 A maximum, branch 1200 A maximum
G. Switch Board
Rated 600 V, 480 V, 240 VAC, 250 VDC
6000 A maximum main bus rating
Main Devices:
MCCB, 400 – 2500 A, fixed or drawout
Magnum DS ACB, 800 – 5000 A, fixed or drawout
Feeder devices:
MCC, 800 – 2500 A, fixed
Magnum DS ACB, 800 – 4000 A
Available in NEMA 1 & 3R enclosure
Front Accessible
H. Switchgear
1. Magnum DS Switchgear
Rated 600 VAC maximum
Using Magnum DS ACB until 6000 A
Vertical and cross bus rating are 2000, 3200, 4000, 5000, and 6000 Ampere 8000 & 10000 A continuous cross bus ratings are also available
Silver-plated copper main buses are standard. The plating is over the entire length of the bar, not just at the joints
Standard bracing is 100 kA
Available in NEMA 1 & 3R enclosure
2. Arc Resistant Switchgear
- Low voltage arc-resistant switchgear
protects operating and maintenance
personnel from dangerous arcing
faults by redirecting or channeling the
arc energy out the top of the
switchgear, regardless of the
origination location of the arc
- Patented bellows design allowing
drawout of breaker into the
disconnected position with the door closed, while simultaneously
protecting the operator from any dangerous gasses during an arc event
I. Contactor
1. NEMA Contactor
Size 00 – 8, max 900 HP Motor
IEC Contactor
7 – 1215 A, max 900 HP Motor
HVAC Contactor
Designed for service in applications such as refrigeration, air conditioning and resistance heating
DPCK Contactor
Designed for applications include mining equipment, welding equipment, heating & air conditioning applications & other loads that require a compact heavy-duty contactor rated up 1500 VAC
2. DC Contactor
Capable switching up to 2000 VDC loads, rated at 1400 A continuous
Lighting Contactor
Designed to handle the switching of tungsten or ballast ( fluorescent, mercury / sodium vapor, and quartz) load
Available in electrically held, mechanically held, and magnetically latched
Number of poles until 12 poles for 30 A rated
For magnetically latche rated until 400 A
J. Soft Starter
1. Type TL, S701 Solid State Controller
- Low cost option for soft starting small 3-phase motor until 15HP
- Provide the overload protection for the motor
2. Type S752, S801, S811 Solid State Starter
Rated up to 690VAC, 11 – 1000 Ampere
Operations: voltage ramp start, current limit start, kick start, soft stop, and optional pump control
Equipped with DIM ( Digital Interface Module) for metering, monitoring & diagnostic capabilities
Protective features: overload, jam, stall, over temperature, phase loss / imbalance / reversal, shorted / open SCR detection, low current, low / high voltage
K. Adjustable Frequency Drive
1. MVX 9000 Micro Drive
Provide variable speed control for three phase motor applications up to 10 HP
Sensorless Vector Control with auto tuning
Built-in dynamic braking chopper & serial
communication ( RS-485) port
2. SVX 9000 General Purpose Drive
Robust design, proven 500, 000 hours MTBF
Rated: 380 – 500V, 1 – 1900 HP 525 – 690V, 2 – 2000 HP
Available in open chassis, NEMA 1 & 12 enclosure
3. CPX 9000 Clean Power 18 Pulse Drive
Use advanced 18-pulse, clean power, technology that significantly reduces line harmonics at the drive input terminals, resulting in one of the purest sinusoidal wave forms available
Applications in the industries where harmonics are a concern
Rated: 480VAC, 25 – 700 HP in NEMA 1 enclosure
4. LCX 9000 Liquid Cooled Drive
The LCX9000 drives are liquid-cooled products that utilize potable water or a water-glycol mixture as a cooling medium
Space savings up to 70% compared to just the power module of a similarly rated air-cooled drive
Rated: 380 – 500V, 10 – 1800 HP; 525 – 690V, 200 – 2000 HP
L. Enclosed Control
Enclosure type 1, 12, 3R, 4, 4X, and 7/ 9 Hazardous Location
Component inside the enclosure:
Motor Disconnecting Switch: circuit breaker and disconnect switch
Motor controller: contactor, starter, soft starter, and inverter
Power Supply: phase to neutral and control power transformer ( CPT)
Cover Control: selector switch, push button, and pilot light
M. Motor Control Center ( MCC)
1. Freedom 2100 MCC
Fabricated in Fayetteville, USA
Modular, framed design permits structure arrangement to be tailored to exactly meet any control & distribution requirement
NEMA 1, 2, 12, and 3R enclosure
Copper horizontal bus 600 – 3200 A
Fully rated copper vertical bus 300 – 1200 A
42kA, 65kA, and 100kA bus bracing
Labyrinth barriers for insulated & isolated vertical bus
All components are wired in accordance with NEC and UL standards
2. FlashGard MCC
FlashGard addresses the dangers associated with an arc flash event and help prevent injury from electric shock, arc-flash burn, and arc-blast impacts
FlashGard offers an insulated horizontal bus, an insulated labyrinth vertical bus, shutters to isolate the vertical bus when a unit is removed, and finger-safe components inside the units
To reduce the time-available fault current FlashGard is offering an Arc Reduction Maintenance System ( ARMS) , applied to the breaker feeding the MCC to reduce trip time during an arc flash
Maintaining a closed-door unit
Removing voltages dangerous to life
N. Metering Devices
1. IQ 100
Low cost meter, no communication
Monitored values: current, voltage, & frequency
2. IQ 200 & IQ 300
Phase current, voltage ( L-L, L-N) , frequency, power factor
System & per-phase power ( watthours, varhours, VA hours)
System demand ( watt, VA, var demand)
True rms metering of distorted current & voltage up to the 31st harmonic ( % THD)
Recorded min & max of most values
Digital & analog I/ O
Built in INCOM or Modbus communication
3. IQ DP-4000 & IQ Analyzer
Monitored values: rms sensing, current, voltage, frequency, power factor, power, energy, % THD current & voltage, min & max values
Digital & analog I/ O
Built in INCOM / Ethernet / Modbus communication
IQ DP-4000 had protective & event alarming features: under/ over voltage, phase loss / reversal / unbalance, and
optional current & voltage demand threshold
IQ Analyzer had
LCD display
4. Power Xpert
2 pieces design: Power Xpert Meter Module & Power Xpert Graphic Display ( support up to 16 PX Meter Module)
Optional Power Xpert Embedded Web Server
Both graphic display & web server present real time, historical, & event information in a browser-style graphical format to interpret key circuit such as:
Current loading, voltage & power level, power factor, energy usage, power quality measurement, harmonic plot, and disturbance & transient waveform
Support E-mail Notification with the optional LAN/ WAN Ethernet Comm Expansion Card
O. Protective Relay
1. Manual / Non-Automatic Transfer Switch
Totally enclosed for maximum arc suppression and isolation during power transfer
Permits safe & convenient manual transfer of power under load via external pushbutton initiated operation
Rated 600 VAC, 30 – 4000 A in 2, 3, and 4 poles
Available in open, NEMA 1, 3R, 12, 4 and 4X Enclosure
2. MP – 3000 / 4000 Motor Protection Relay
Provide motor overload, stall, short circuit, phase unbalance, over/ under voltage, underpower, power factor, & ground fault protection
MD – 3000 Motor / Generator Differential Relay
P. MV Circuit Breaker
1. VCP-W Medium Voltage Circuit Breaker
Common platform: 5– 38 kV, 16– 75 kA, 600– 6000A
Numerous product variations: narrow design, extra capability and generator breaker designs
Built and tested to meet ANSI, IEC and GB standards
2. VCP-T Medium Voltage Circuit Breaker
Common platform: 5– 15 kV, 16– 40 kA, 600– 2500A
Compact: 60% smaller & 50% lighter than comparable breakers
Designed for use where space is at a premium
Spring & magnetic actuated mechanisms are available
Built and tested to meet ANSI and IEC standards
Q. MV Contactor
SL Medium Voltage Power Contactor
Using leading edge vacuum technology
Voltage range 2200 to 7200 V
Ampere rating: 160 / 200 / 360 / 400 / 800 A with induction motor horsepower until 10000 HP
Field adjustable coil voltages & drop-out times
Long life – 100, 000 electrical operations and over 1 million mechanical operations
Universal altitude versions ranging from -3500M to + 5000M
R. MV Soft Starter
MV 811 Medium Voltage Soft Starter
Intelligent choice for MV mechanical components to avoid coupling & shaft damage, prevent rotor & winding failure, and stop drive belt squeal and reakage
Ratings: 100 to 1500 hp at 2400 volts 200 to 2500 hp at 4160 volts
NEMA 1, 1A, 12 and 3R enclosures
Operations: ramp start, current limit start, kick start, soft stop, and optional pump control
Internal run bypass contactor which significantly reduces the internal heating created by the SCRs
S. MV adjustable Frequency Drive
AMPGARD SC 9000 MV Drive
Designed for use with induction or synchronous motor at 2400 to 4160 volts up to 5750 horsepower
The SC 9000’ s integrated phase shifting isolating transformer/ 24 pulse converter, coupled to a 3-level inverter topology, assures minimum component usage and reduces harmonics output.
Specialized design and high-density packaging yields the smallest medium voltage drive in the industry
The SC 9000 modular roll-in/ roll-out inverter design significantly reduces MTTR
Can be supplied as a stand-alone drive or directly connected to other AMPGARD products
T. MV Motor Starter
AMPGARD Motor Starter
Designed as integrated, complete units precisely matched to motor ratings, at 2200 – 7200 volts, up to 8000 Hp
With an innovative design that enables easier installation, maintenance, and long life,
Starters for motors: full voltage, reduced voltage ( either reactor or autotransformer type) , soft starter and drive
Full coordination between fuse and contactor provides seamless protection
U. MV Switchgear
1. MVS Fusible Switch
Provides safe, reliable switching and fault protection for MV circuits rated from 2.4 kV through 38 kV
Ideal for applications in a lower duty cycle operation environment, while providing a cost-effective option
Continuous and load-break ratings: 600 A and 1200 A available at 5kV and 15kV
Availabe in fusible and non fusible
Visibility of actual blade position improves safety by providing positive assurance of circuit de-energization
Can be equipped with motor operator to provides the safety, convenience, and coordination inherent in remote switch operation
2. MEF Front Accesible Switchgear
Flexible, cost effective & space-efficient MV switchgear
Available in ratings of 5 & 15 kV with 600, 1200, & 2000 A
Truly front accessible construction eases installation, maintenance, and saves space in an electrical room
Using Eaton’ s VCP-TL breaker’ s integral self-powering trip unit eliminates the need for an external power source in addition to a linear actuator that boasts 100, 000 mechanical operations
Flexible configurations and standard building blocks provide easy scalability
3. MEB / MSB Switchgear
Eaton' s MEB / MSB switchgear is an integrated assembly of a visible load-break disconnect switch, bus, fixed / drawout mounted vacuum circuit breaker, and control devices, which are integrated electrically & mechanically for circuit protection
Ratings: 4.76 to 15 kV, 1200 A max
Using Eaton’ s VCP-T breaker’ s up to 1200 A
Also available with Arcflash Reduction Maintenance System
4. VCP-W Metal Clad Switchgear
VCP-W metal-clad switchgear with type VCP-W vacuum breakers, provides centralized control and protection in industrial, commercial, and utility installations involving generators, motors, feeder circuits, and transmission and distribution lines.
Ratings from 4.76 kV through 38 kV,
Maintenance requirements are minimized by the use of enclosed long-life vacuum interrupters, and the component arrangements and drawers allow easy access
Tampilkan Lebih Banyak